Representative disinfectant water and its production method.
A detailed explanation of the typical methods for generating sterilizing water.
Here are the representative methods for generating disinfectant water: 1) Strongly acidic water ⇒ Membrane electrolysis method, anode → Since the pH is below 3.0, chlorine gas vaporizes quickly, leaving residual salt and causing severe metal corrosion. 2) Weakly acidic hypochlorous acid water ⇒ Membrane electrolysis method, anode or bipolar mixed → With a pH of 3.0 to 5.0, it falls within the chlorine gas generation range, resulting in a chlorine smell. Residual salt can remain, making metal corrosion likely. 3) Mildly acidic hypochlorous acid water ⇒ Non-membrane electrolysis → Due to the low production rate per unit time, a storage tank is necessary. 4) Two-liquid mixing method of dilute hydrochloric acid and sodium hypochlorite using a pump → Since the concentrated solution passes directly through the pump and piping, the equipment is prone to deterioration. 5) Two-liquid mixing method of dilute hydrochloric acid and sodium hypochlorite using differential pressure suction Clear Fit Fine CF-1000 Next *For more details, please refer to the PDF document or feel free to contact us.*
- Company:シナプス・ジャパン
- Price:Other